BENETECH GM510 vs GM520: Do You Need a USB Pressure Record?

Choose the BENETECH GM510 if you need a handheld differential-pressure reading that you can write into a job sheet and its range, resolution and fittings match the job. If the job requires a file captured by a computer, check the GM520 first. EkoDeluxe lists USB on the GM520. Ask for a sample export and confirm software support before choosing it for a report that depends on the file.

What does the pressure record need to show?

Suppose you need to record a pressure difference on an air test bench at one steady operating setting. If the job sheet accepts a manual entry, record the time, displayed value and unit, the two measurement points and the port order. Include the operating setting so someone else can interpret the reading. The GM510 listing identifies two ports and a HOLD control. Consult the instructions for the supplied model when you use the controls.

A changing pressure needs a different record. Decide whether a series of readings taken at agreed times meets the requirement or whether the report needs time-stamped data from software. For a file-based report, check sample interval, timestamps, units and export format with the system you will actually use.

Which BENETECH should you shortlist?

Compare the recording requirements for the GM510 and GM520
Job requirement Buying decision
One signed differential reading for a manual log Shortlist the GM510 and confirm the required resolution, accuracy and supplied fittings for the two measurement points.
A pressure file for a computer-based report Shortlist the USB-listed GM520 and verify the software, sampling and export details for the supplied revision before buying.
Repeat readings after a change in operating conditions Agree the sampling interval and required record first. Manual logging can work for agreed spot readings. A prescribed file or trace calls for verified data capture.

The EkoDeluxe listings give both models a ±10 kPa measuring span. Confirm the allowable conditions at each port and the resolution and uncertainty for the smallest change you need to interpret. The GM510 faceplate lists REC. Confirm exactly what the supplied unit records and whether the data can be retrieved if either point matters to the job.

Confirm the GM510 kit before ordering

Bring the expected signed differential, the method’s unit and tolerance, the test-point fittings and the required record format. Ask the supplier to confirm the allowed media and port pressure and the hose and adaptor contents for the exact kit. The offer below opens the UK listing for SKU EKO-GM510.

View the BENETECH GM510 kit and UK buying options